 DS78TBR-E is an inferential, multi-stream, wet dial, straight reading type meter for cold water, and it’s suitable for domestic use. Brass body, internal mechanisms are made from wear-resistant, waterproof, antimagnetic and antiscaling plastic material. No leak, mechanical transmission not effected by external magnetic fields or ferrous particles in water.   SPECIALITY: * Internal filter of adequate filtering section. * Large measuring range and high flow accuracy * Low start-up flow, high sensitivity, long life of service time.   WORKING CONDITION: * The max. admissible pressure: 1.6MPa(16bar) * Water temp. : not more than 50℃
 
 Maximum permissible error: Between qt (included) and qs is ±2%; Between qmin and qt (excluded) is ±5%. NOTE: The technical data conform to ISO4064 standard, class B.
 FLOW-ERROR CURVE
  
 
 SPECIFICATION AND OVERAL DIMENSIONS
 
| Description | Unit | Hydraulic data and dimensions |  
| Nominal size  | mm | 15 | 20 | 25 | 32 | 40 | 50 |  
| inch | 1/2 | 3/4 | 1 | 11/4 | 11/2 | 2 |  
| Overload flow-rate (qs) | m3/h | 3 | 5 | 7 | 12 | 20 | 30 |  
| Permanent flow-rate (qp) | m3/h | 1.5 | 2.5 | 3.5 | 6 | 10 | 15 |  
| Transitional flow-rate (qt) | l/h | 120 | 200 | 280 | 480 | 800 | 3000 |  
| Minimum flow-rate (qmin) | l/h | 30 | 50 | 70 | 120 | 200 | 450 |  
| Min. reading  | l | 0.05 | 0.05 | 0.05 | 0.05 | 0.05 | 0.05 |  
| Max. reading  | m3 | 99999 | 99999 | 99999 | 99999 | 999999 | 999999 |  
| Nominal pressure  | MPa | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 |  
| ΔP at the qs | MPa | 0.06 | 0.08 | 0.05 | 0.09 | 0.085 | 0.085 |  
| L | mm | 165 | 190 | 260 | 260 | 300 | 300 |  
| I | mm | 243 | 286 | 376 | 376 | 438 | 438 |  
| H  | mm | 108 | 108 | 126 | 126 | 170 | 170 |  
| B | mm | 98.5 | 98.5 | 98.5 | 98.5 | 130 | 130 |  
| G  | inch | G3/4B | G1B | G11/4B | G11/2B | G2B | G21/2B |  
| R | inch | R1/2 | R3/4 | R1 | R11/4 | R11/2 | R2 |  
| Weight  | Without connections | Kg | 1.20 | 1.43 | 2.34 | 2.42 | 3.77 | 4.72 |  
| With connections | 1.37 | 1.69 | 2.79 | 3.05 | 4.47 | 6.12 |  OVERALL DIMENSIONS                                                                    PRESSURE LOSS CURVE
 
  |